Roving GC/MS: Mapping VOC Gradients and Trends in Space and Time

McClennen, W.H.; Vaughn, C.L.; Cole, P.A.; Sheya, S.A.N.; Wager, D.J.; Mott, T.J.; Dworzanski, J.P.; Meuzelaar, H.L.C. and Arnold, N.S.
Field Analytical Chemistry and Technology, 1(2):109-116, 1996. Funded by Hewlett Packard and ACERC.

Obtaining representative VOC (volatile organic compound) measurements in ambient environments that exhibit complex concentration gradients and/or trends is difficult when relying upon limited numbers of analyses obtained by simple pooling or averaging techniques. A more effective approach is to perform large numbers of analyses over a period of time to permit detailed mapping of profiling of local gradients and trends. Until recently, use of GC/MS (gas chromatography/mass spectrometry) techniques for rapid profiling or mapping operations was not feasible because of sample speed limitations. This article describes a roving GC/MS system based on the combination of a Hewlett-Packard model 5972 MSD (mass selective detector), a FemtoScan Enviroprobe repetitive vapor sampling inlet with short capillary GC column, and Alcatel Micro HV oil-less vacuum pump stack and a Pentium notebook PC running under Windows 95. The roving system is further equipped with differential GPS (global positioning system) and radio transceiver capabilities thereby permitting remote tracking of vehicle location and local VOC concentrations. Laboratory tests demonstrate lower detection limits of approx 4 ppb for BTX (benzene, toluene, and zylene), corresponding to minimum detectable quantities of a mixture of volatile ketones. Demonstrated outdoor performance, using a zero-emission electric vehicle, includes measurement of low ppb BTX levels along a 6 km urban route at 15 s (~ 150 m) intervals while moving at an estimated average speed of 35 km/hr. Indoor measurements of toluene concentrations in the low to mid ppm range at 6 s (~5 cm) intervals along a 6 m long path reveal a high degree of spatial and temporal variability in VOC concentrations. Mobility, specificity, sensitivity and speed of the roving GC/MS method make this a promising candidate method for rapid outdoor and indoor screening, monitoring and mapping of VOCs.

Field Evaluation of a Prototype Man-Portable GC/MS

Arnold, N.S.; Du, W.H.; Sheya, S.A.N.; Mihamou, H.; Dworzanski, J.P.; Hall, D.L.; McClennen, W.H. and Meuzelaar, H.L.C.
Proceedings of the Ninth International Symposium On Field Screening Methods for Hazardous Wastes and Toxic Chemicals, 2:903-910, 1996. Funded by ACERC, US Army Electrical Research Development and Engineering Center.

In recent years, a man-portable gas chromatography/mass spectrometry (GC/MS) system has been developed based on a Hewlett-Packard 5971 MSD and a unique automated vapor sampling (AVS) transfer-line (TL) GC system for direct sampling of ambient chemical vapors [1,2]. The vacuum system and power supplies were replaced to facilitate operation on 24 V DC batteries for up to 4 hours after startup on a transportable docking station. The gas chromatography was performed on a short (2 m) capillary column under isothermal conditions in a small oven to minimize power usage. Repetitive samples were taken at 10 to 60 s intervals using an automated vapor-sampling inlet.

In initial testing, the prototype system has been used for monitoring of gasoline vapors. Ambient levels of 6.0 ppm benzene, 4.1 ppm toluene, 0.22 ppm ethylbenzene, 1.1 ppm m-and p-xylene and 0.25 ppm 0-xylene were measured near a busy gas station. The gradient mapping or source tracking capabilities of the backpack-mounted system have also been demonstrated in tests with a simulated gasoline leak.

This paper will describe recent work to further evaluate the capabilities and limitations of the prototype system. Results will be described in terms of the practical utility of portable GC.NS for identification and quantification of unknown vapors.

Design Considerations for a Novel Miniaturized Tandem GC Method for Field Screening Applications

Sheya, S.A.N.; Dworzanski, J.P.; McClennen, W.H.; Meuzelaar, H.L.C. and Arnold, N.S.
Proceedings of the Ninth International Symposium On Field Screening Methods for Hazardous Wastes and Toxic Chemicals, 1:213-220, 1996. Funded by ACERC.

Development of a potentially field-portable tandem GC (GC/GC) method involving a novel, dynamic coupling between two short capillary GC columns-each of which is independently optimizable with regard to temperature and flow-is described. The relatively slow (5-25 sec wide), GC peaks eluting from the first (1.2 m x 530 µm) column are sampled repetitively at 1-5 sec. Intervals into the second (0.8 m x 100 µm) column. Dynamic coupling by means of fluidic AVS (Automated Vapor Sampling) technology, rater than through trap-and-desorb interfaces, reduces power requirements. Further power reduction is achieved by isothermal operation of both columns. If properly designed and optimized the sensitivity of dynamic GC/GC techniques should approach that of one-dimensional GC, depending on the type of detector used. Since a universally responsive, subambient pressure, low weight and low power detector for field-portable GC/GC has not yet been found, a Hewlett Packard MSC (Mass Selective Detector) was used throughout the present study. At a maximum scan rate of 35 spectra (over 5 amu mass range), the minimum practical GC peak width eluting from the second column is limited to approximately 100 msec. The feasibility of producing comprehensive, two-dimensional chromatograms of multicomponent mixtures, volatile compounds, including C3-C6 ketones, is demonstrated.

Hyphenated Techniques: The Next Generation of Field-Portable Analytical Instruments?

Meuzelaar, H.L.C.; McClennen, W.H.; Dworzanski, J.P.; Sheya, S.A.N.; Snyder, A.P.; Harden, C.S. and Arnold, N.S.
Proceedings of the Ninth International Symposium On Field Screening Methods for Hazardous Wastes and Toxic Chemicals, 1:38-46, 1996. Funded by ACERC, Consortium for Fossil Fuel Liquefaction Science, US Army Electrical Research Development and Engineering Center, Hewlett Packard, Finnigan MAT Corporation, and Femto Scan Corporation.

The first field-portable (i.e., transportable) hyphenated analytical instruments, including commercially available MS/MS and GC/MS systems as well as a specially built GC/MS system, were introduced during the past seven years. Since then further miniaturization and ruggedization of hyphenated systems by several laboratories has resulted in fully man-portable (backpack and briefcase style) GC/MS systems and a hand portable GC/IMS prototype. The main pitfall to be avoided in developing a hyphenated, field portable system is incompatibility between the coupled techniques. Carefully designed hyphenated techniques incorporating compatible methods such as GC and MS can provide dramatic increases in resolution and chemical specificity which may be traded for speed or sensitivity gains, if needed. Novel developments currently underway in the laboratory include roving GC/MS platforms, personalized GC/IMS devices, high speed GC/GC methods and, last but not least, Virtual Reality techniques.

1993

On-Line Monitoring of Formaldehyde in Combustion Gases Using Gas Chromatography/Mass Spectrometry

McClennen, W.H.; Sheya, S.A.N.; Arnold, N.S.; Meuzelaar, H.L.C.; Larsen, F.S. and Silcox, G.D.
Incineration of Hazardous Wastes-2; Toxic Combustion By-Products:545-555, (in press). Funded by Consortium for Fossil Fuel Liquefaction and ACERC.

This paper describes a method for on-line gas chromatography/mass spectrometry (GC/MS) of formaldehyde in combustion gases. The method uses a recently developed vapor-sampling inlet to monitor the concentration of formaldehyde and other products of incomplete combustion (PICs) from the burning of plain and phenol-formaldehyde resin treated wood chips. Other PICs that were simultaneously monitored included ketene, propylene, propyne and acetaldehyde. The direct analysis method has detection limits of less than 1 ppm for the reactive formaldehyde and excellent selectivity for determinations in the complex mixtures of combustion products. The rapid sampling technique allows monitoring of transient events of only a few minutes or less duration. Examples of the technique include the detection of sample line problems and the comparison of PIC concentrations from different points in the combustion exhaust stream.

1991

On-Line Monitoring of Formaldehyde in Comubustion Gases Using Gas Chromatography/Mass Spectrometry

McClennen, W.H.; Sheya, S.A.N.; Arnold, N.S.; Meuzelaar, H.L.C.; Deng, X.-X.; Larsen, F.S. and Silcox, G.D.
Combustion Science and Technology, 1991 (in press). Funded by ACERC.

This paper describes a method for on-line gas chromatography/mass spectrometry (GC/MS) of formaldehyde in combustion gases. The method uses a recently developed vapor-sampling inlet to monitor the concentration of formaldehyde and other products of incomplete combustion (PICs) from the burning of plain and phenol-formaldehyde resin treated wood chips. Other PICs that were simultaneously monitored included ketene, propylene, propyne and acetaldehyde. The direct analysis method has detection limits of less than 1 ppm for the reactive formaldehyde and excellent selectivity for determinations in the complex mixtures of combustion products. The rapid sampling technique allows monitoring of transient events of only a few minutes or less duration. Examples of the technique include the detection of sample line problems and the comparison of PIC concentrations from different points in the combustion exhaust stream.

1990

Development of Novel, Mass Spectrometric Combustion Monitoring Techniques

McClennen, W.H.; Arnold, N.S.; Sheya, S.A.N.; Lighty, J.S. and Meuzelaar, H.L.C.
Preprints for Papers Presented at the 200th ACS National Meeting, 35 (3), 713-720, Washington, D.C., 1990. Funded by ACERC.

An on-line gas and vapor analysis method has been developed to monitor combustion products by short column ("transfer line") Gas Chromatography/Mass Spectrometry. An automated vapor-sampling inlet with only inert materials (quartz and fused silica) in the sample path is utilized to introduce flue gases into a 1 m long "transfer line" capillary GC column for rapid, repetitive chromatographic separation of products. The column effluent is introduced directly into the source of an ion trap type mass spectrometer. Combustion products from a gas fired rotary kiln were monitored by this method using a standard Ion Trap Detector (ITD). Detection limits of 20 to 50 ppb were obtained for various substituted benzenes. Monitoring of polycyclic aromatic hydrocarbons (PAHs) from the thermal desorption of contaminated soils in a fixed bed reactor utilized a modified Ion Trap Mass Spectrometer (ITMS). Varying isothermal column temperature allowed analysis of PAHs from naphthalene through 6 ring PAHs. The ITMS system provides higher sensitivity (~4 ppb for benzene) in addition to tandem MS and chemical ionization capabilities for unambiguous identification of combustion products incompletely resolved by the transfer line GC approach.

On-Line GC/MS Sampling of Exhaust Gas from a Rotary Kiln Simulator

Lighty, J.S.; Wagner, D.; Deng, X.-X.; Pershing, D.W.; McClennen, W.H.; Sheya, S.A.N.; Arnold, N.S. and Meuzelaar, H.L.C.
AWMA Specialty Conference on Waste Combustion in Boilers and Industrial Furnaces, Kansas City, MO, 1990. Funded by ACERC.

An on-line, short-column gas chromatography/mass spectrometry (GC/MS) system has been used to monitor the evolution of trace amounts of hydrocarbons evolving from a material which has been combusted in a rotary-kiln simulator. The system uses the isothermally heated, 1-m long transfer line of an Ion Trap Detector (ITD) as the gas chromatograph. The fused silica capillary normally used in the transfer line is replaced by a 1 m, 0 .15-mm inside diameter, 1.2 micron thick methyl silicone stationary phase (DB-1) GC column. Given the short column length and using a direct vapor sampling inlet, the exhaust gas can be sampled quickly, approximately every 10 s in these experiments. Since the column is isothermal, only a limited range of compounds can be analyzed for any given experiment.