1989

Development of a Mobile Ion Trap Mass Spectrometer for Environmental Monitoring

Meuzelaar, H.L.C.; McClennen, W.H.; Arnold, N.S.; Maswadeh, W.; Reynolds, T.K.; Urban, D.T. and Jones, P.R.
Proc. 37th ASMS Conference on Mass Spectrometry and Allied Topics, Miami Beach, Florida, 1424-1426, 1989. Funded by ACERC (National Science Foundation and Associates and Affiliates), the State of Utah, US Department of Energy, the Department of Defense Chemical Research Development and Engineering Center and Finnigan-MAT Corp.

The objective of the work reported here is to develop a compact, mobile mass spectrometer with EI, CI and MSn capabilities. Moreover, the mobile MS system should be capable of analyzing gases, vapors and aerosols in air at low ppb levels while allowing positive identification of individual components in complex mixtures. In view of the size and weight restrictions inherent in the mobility requirement, a special miniaturized version of the Finnigan MAT Ion Trap Mass Spectrometer (ITMS?) was constructed in close collaboration with the manufacturer. This MINITMASS Miniaturized Ion Trap Mass Spectrometer) system is equipped with automatic gain control, automatic reaction control, selective mass storage and axial modulation options, in addition to the required EI/CI and MSn operating modes. The 2x2x2 ft MINITMASS module is mounted within a 6 ft high mobile rack together with all gas supplies, pumps, inlet controls and a PC 80386 workstation. The entire system requires approx. 1000 W of ac power. A 6x7x8 ft, self-contained mobile laboratory module, which fits on a standard 3/4 ton pick-up truck, enables operation of the MINITMASS in remote locations and rugged terrain. Also, the MINITMASS system can be remotely controlled from a distance up to several miles using a second PC workstation, and Carbon Copy© software. A direct air-sampling inlet enables repetitive collection of 10-50 microliter air samples at 15-60 sec intervals. Use of "transfer line chromatography" provides additional resolution and specificity for complex mixtures. Minimum detectable levels of gases and vapors in air are in the low to medium ppb range without the use of concentration devices. Alternatively, a special automated inlet enables electrostatic precipitation of air particulate matter on a ferromagnetic filament with subsequent analysis by Curie-point pyrolysis (GC)/MSn. The system has been successfully operated in the desert (at temperatures up to 100 F), as well as under a variety of indoor conditions, e.g., for monitoring laboratory-scale combustion reactors.

A Mobile, Tandem Ion Trap Mass Spectrometer System for Environmental Monitoring of Vapors

Arnold, N.S.; McClennen, W.H.; Maswadeh, W.; Urban, D.T.; Reynolds, T.K.; Jones, P.R. and Meuzelaar, H.L.C.
Proceedings of the 1989 U.S. Army Chemical Research Development and Engineering Center Scientific Conference on Chemical Defense Research, 1989. Funded by ACERC (National Science Foundation and Associates and Affiliates), the State of Utah, US Department of Energy, the Department of Defense Chemical Research Development and Engineering Center, Geocenter, Inc. and Finnigan-MAT Corp.

A fieldable, Miniaturized Ion Trap Mass Spectrometer (MINITMASS) was constructed for tandem mass spectrometry of environmental vapors. Furthermore, a vapor sampling inlet for transfer line gas chromatography/mass spectrometry was developed which permits direct on-column introduction of atmospheric vapor samples. The transfer line gas chromatography/tandem mass spectrometry combination provided for direct introduction of complex vapor samples with short overall analysis times for on-line monitoring of changing environmental conditions. Work to date has shown the capability for low ppb analysis of substituted aromatic hydrocarbons, corresponding to subpicogram quantities per compound, in MS as well as MS/MS mode.